Switching cam encoder NOCN/S3 PLd
Prices plus VAT plus shipping costs
Delivery time approx. 60 business days
Bestellschlüssel
Would you like more? 3
This involves a play-free electronic switching cam encoder (abbreviated to: NOCN) with two galvanically separated safety switching outputs (cams), which can be set by the customer and which are activated or deactivated depending on the relevant position of the drive shaft. An absolute mulitturn encoder with CANopen interface, adjustable parameters and an electronic switching cam module is realized in the compact housing. A separate controller unit monitors the function of the cams.
The encoder's CANopen position signal and the switching outputs can be parameterised separately. The parameterisation (cam limits, resolution, measuring range a.s.o.) has to be verified to the NOCN via a checksum. This checksum can be calculated by a TWK program or the standard algorithm recommended by the CiA. After verification the device can be set operational.
Preset and resolution of the position signal also influence the cams which refer to the position signal. Parameterisation is carried out via the relevant CANopen objects in accordance with the encoder profile according to CiA, DS 406, revision 4.0.2.
The 64 mm housing styles can be supplied with an ATEX certificate to Zone 2/22 on request.
Product category: | Switching cam encoders |
Design: | 64 mm |
Single- or Multiturn: | Multiturn |
Flange and shaft: | Clamped flange, clamped shaft 12 mm inside diameter with groove Clamped flange, shaft 12 mm for measurement gear ZRS Clamped flange, shaft 12 mm with feather key Clamped flange, shaft 12 mm with flattened area |
Housing material: | Aluminium Stainless steel 1.4305 Stainless steel 1.4404 |
Number of switching outputs: | 2 switching outputs 4 switching outputs (on request) |
Resolution: | 4096 = 12-bit 8192 = 13 Bit 16384 = 14 bit (on request) 32768 = 15 bit (on request) |
Code type: | Binary Slewing ring functionality (only with NOCN without switching contacts) |
Profile: | S0: Safety version with safety switching outputs S3: PLd certified |
Electrical connection: | S2: 2 device plugs M12, radial S3: 3 device connectors M12, radial T2: 2 device plugs M12, axial (on request) T3: 3 device connectors M12, axial (on request) |
Galvanic seperation: | V1: -UB ǂ CAN_GND ǂ screen/housing (recommended) V2: -UB = CAN_GND ǂ screen/housing V3: -UB = CAN_GND = screen/housing |
Interface: | CANopen Safety |
Electrical and/or mechanical variant: | Standard |
Certification: | PLd |
Special feature: | PLd Speed monitoring |
more
Array ( [15] => Array ( [name] => Datenblaetter [files] => Array ( [de_DE] => Array ( [0] => Array ( [id] => 3124 [description] => Datenblatt 13099 [filename] => https://www.twk.de/media/pdf/85/96/34/13099md0.pdf [size] => 1615078 [attributes] => Array ( ) ) ) [en_GB] => Array ( [0] => Array ( [id] => 3125 [description] => Data sheet 13099 [filename] => https://www.twk.de/media/pdf/ab/22/bb/13099me0.pdf [size] => 1563658 [attributes] => Array ( ) ) ) ) ) [17] => Array ( [name] => Handbücher [files] => Array ( ) ) [19] => Array ( [name] => Zertifikate [files] => Array ( [en_de] => Array ( [0] => Array ( [id] => 3128 [description] => Zertifikat 15806 [filename] => https://www.twk.de/media/pdf/a9/c1/54/15806ab0.pdf [size] => 1217948 [attributes] => Array ( ) ) ) ) ) [21] => Array ( [name] => Step Dateien [files] => Array ( ) ) [16] => Array ( [name] => GSD-ESD-ESI [files] => Array ( ) ) [18] => Array ( [name] => Anleitungen [files] => Array ( ) ) [20] => Array ( [name] => Software [files] => Array ( [z] => Array ( [0] => Array ( [id] => 3129 [description] => SafetyCRC Software [filename] => https://www.twk.de/media/archive/b6/d4/8d/SafetyCRC-V2-0-7.zip [size] => 88771635 [attributes] => Array ( ) ) ) ) ) [56] => Array ( [name] => Technische Dokumentation [files] => Array ( ) ) [22] => Array ( [name] => Sonstige [files] => Array ( [en_GB] => Array ( [0] => Array ( [description] => UKCA Declaration of Conformity [filename] => https://twk.de/media/pdf/89/01/24/16569ae0.pdf ) [1] => Array ( [id] => 3126 [description] => Manual 13100 [filename] => https://www.twk.de/media/pdf/81/6c/bf/13100te0.pdf [size] => 3314251 [attributes] => Array ( ) ) [2] => Array ( [id] => 3127 [description] => Kennwertbibliothek [filename] => https://www.twk.de/media/archive/05/74/1e/VDMA_Safety_Libary.zip [size] => 72435 [attributes] => Array ( ) ) ) [en_de] => Array ( [0] => Array ( [description] => Reach Konform/compliant [filename] => https://twk.de/media/pdf/97/34/49/15286fb0.pdf ) [1] => Array ( [description] => RoHS Konform/compliant [filename] => https://twk.de/media/pdf/7f/81/9f/13284hb0.pdf ) ) [globe] => Array ( [0] => Array ( [description] => CE Declaration of Conformity [filename] => https://twk.de/media/pdf/0d/49/0e/12467rx0.pdf ) ) ) ) ) 1