Switching cam encoder NOCN79/S3 PLd

PLD
Image may differ
Switching cam encoder NOCN79/S3 PLd
Switching cam encoder NOCN79/S3 PLd
   
Price on request

Prices plus VAT plus shipping costs

Delivery time approx. 60 business days

Product group:

Design:

Flange and shaft:

Housing material:

Number of switching outputs:

Resolution:

Code type:

Measuring range:

Profile:

Electrical connection:

Galvanic separation:

Interface:

Electrical and/or mechanical variant:

More Options Fewer options

Bestellschlüssel

NOCN 79 KZ A 2 4096 R 4096 S3 S2 V1 N 01

Would you like more? 3

Play-free clamping coupling Models KK14 Play-free clamping coupling Models KK14
Nicht verfügbar
Price on request
Bellows couplings model BKK Bellows couplings model BKK
Nicht verfügbar
Price on request

Quantity

This involves a play-free electronic switching cam encoder (abbreviated to: NOCN) with two (At... more
Product information "Switching cam encoder NOCN79/S3 PLd"

This involves a play-free electronic switching cam encoder (abbreviated to: NOCN) with two (At version 79 four) galvanically separated switching outputs (cams), which can be set by the customer and which are activated or deactivated depending on the relevant position of the drive shaft. An absolute mulitturn encoder with CANopen interface, adjustable parameters and an electronic switching cam module is realized in the compact housing. A separate controller unit monitors the function of the cams.

The encoder's CANopen position signal and the switching outputs can be parameterised separately. The parameterisation (cam limits, resolution, measuring range a.s.o.) has to be verified to the NOCN via a checksum. This checksum can be calculated by a TWK program or the standard algorithm recommended by the CiA. After verification the device can be set operational.

Preset and resolution of the position signal also influence the cams which refer to the position signal. Parameterisation is carried out via the relevant CANopen objects in accordance with the encoder profile according to CiA, DS 406, revision 4.0.2. 

The 79 mm housing styles can be supplied with an ATEX certificate to Zone 2/22 on request.

Product category: Switching cam encoders
Design: 79 mm
Flange shape: 79 mm
Single- or Multiturn: Multiturn
Flange and shaft: Clamped flange, clamped shaft 12 mm inside diameter with groove
Clamped flange, shaft 12 mm for measurement gear ZRS
Clamped flange, shaft 12 mm with feather key
Clamped flange, shaft 12 mm with flattened area
Housing material: Aluminium
Stainless steel 1.4305
Stainless steel 1.4404
Number of switching outputs: 2 switching outputs. With NOCN79: Up to 4 switching outputs
Resolution: 4096 = 12-bit
8192 = 13 Bit
16384 = 14 bit (on request)
32768 = 15 bit (on request)
Code type: Binary
Profile: C2: CANopen standard
Electrical connection: S2: 2 device plugs M12, radial
S3: 3 device connectors M12, radial
T2: 2 device plugs M12, axial (on request)
T3: 3 device connectors M12, axial (on request)
Galvanic seperation: V1: -UB ǂ CAN_GND ǂ screen/housing (recommended)
V2: -UB = CAN_GND ǂ screen/housing
V3: -UB = CAN_GND = screen/housing
Interface: CANopen Safety
Relais
Electrical and/or mechanical variant: Standard
Certification: EX protection (Atex)
PLd
Special feature: PLd
Speed monitoring
9 Dateien verfügbar.
more
Array
(
[15] => Array
(
[name] => Datenblaetter
[files] => Array
(
[de_DE] => Array
(
[0] => Array
(
[id] => 3142
[description] => Datenblatt 13099
[filename] => https://www.twk.de/media/pdf/85/96/34/13099md0.pdf
[size] => 1615078
[attributes] => Array
(
)
)
)
[en_GB] => Array
(
[0] => Array
(
[id] => 3143
[description] => Data sheet 13099
[filename] => https://www.twk.de/media/pdf/ab/22/bb/13099me0.pdf
[size] => 1563658
[attributes] => Array
(
)
)
)
)
)
[17] => Array
(
[name] => Handbücher
[files] => Array
(
)
)
[19] => Array
(
[name] => Zertifikate
[files] => Array
(
[en_de] => Array
(
[0] => Array
(
[id] => 3146
[description] => Zertifikat 15806
[filename] => https://www.twk.de/media/pdf/a9/c1/54/15806ab0.pdf
[size] => 1217948
[attributes] => Array
(
)
)
)
)
)
[21] => Array
(
[name] => Step Dateien
[files] => Array
(
)
)
[16] => Array
(
[name] => GSD-ESD-ESI
[files] => Array
(
)
)
[18] => Array
(
[name] => Anleitungen
[files] => Array
(
)
)
[20] => Array
(
[name] => Software
[files] => Array
(
[z] => Array
(
[0] => Array
(
[id] => 3147
[description] => SafetyCRC Software
[filename] => https://www.twk.de/media/archive/b6/d4/8d/SafetyCRC-V2-0-7.zip
[size] => 88771635
[attributes] => Array
(
)
)
)
)
)
[56] => Array
(
[name] => Technische Dokumentation
[files] => Array
(
)
)
[22] => Array
(
[name] => Sonstige
[files] => Array
(
[en_GB] => Array
(
[0] => Array
(
[description] => UKCA Declaration of Conformity
[filename] => https://twk.de/media/pdf/89/01/24/16569ae0.pdf
)
[1] => Array
(
[id] => 3144
[description] => Manual 13100
[filename] => https://www.twk.de/media/pdf/81/6c/bf/13100te0.pdf
[size] => 3314251
[attributes] => Array
(
)
)
[2] => Array
(
[id] => 3145
[description] => Kennwertbibliothek
[filename] => https://www.twk.de/media/archive/05/74/1e/VDMA_Safety_Libary.zip
[size] => 72435
[attributes] => Array
(
)
)
)
[en_de] => Array
(
[0] => Array
(
[description] => Reach Konform/compliant
[filename] => https://twk.de/media/pdf/97/34/49/15286fb0.pdf
)
[1] => Array
(
[description] => RoHS Konform/compliant
[filename] => https://twk.de/media/pdf/7f/81/9f/13284hb0.pdf
)
)
[globe] => Array
(
[0] => Array
(
[description] => CE Declaration of Conformity
[filename] => https://twk.de/media/pdf/0d/49/0e/12467rx0.pdf
)
)
)
)
)
1
Viewed